Tornatech is a global leader in fire pump controllers, with headquarters in Canada and manufacturing facilities in Canada, Belgium, and Dubai, plus a strong international network covering more than 125 countries. Its controllers are UL-listed, FM-approved, NFPA-20 compliant, and designed for mission-critical fire protection systems in commercial, industrial, and infrastructure projects worldwide.
These controllers are found in high-rise towers, refineries, airports, oil & gas facilities, industrial plants, and power stations.

Tornatech’s Automatic Battery Chargers are integral to diesel-driven fire pump controllers, ensuring that batteries remain charged, reliable, and ready to start the fire pump engine under emergency conditions. Each control panel is equipped with two battery chargers, one for each battery. Their role is to maintain the batteries voltage to a full charge level.
Excel are now offering complete solution for Tornatech’s Automatic Battery Chargers to Pakistani clients who have installed Tornatech Fire Pump Controllers and facing issues of arranging Tornatech’s Automatic Battery Chargers in Pakistan. We not only supply we also provide you complete solution with supply, installation and commissioning services for Tornatech’s Automatic Battery Chargers in Pakistan
| Feature | Model 1BAT004 | Model 1BAT005 |
|---|---|---|
| Rated Voltage (Us) | 110 – 240V | 110 – 240V |
| Operating Voltage Range | 100 – 264V | 100 – 264V |
| Frequency | 45 – 66 Hz | 45 – 66 Hz |
| Max Current Consumption @ 240V | 1.6A | 2.7A |
| Max Current Consumption @ 110V | 3.1A | 5.1A |
| Max Power Consumption @ 240V | 384VA / 184W | 630VA / 298W |
| Max Power Consumption @ 110V | 341VA / 190W | 552VA / 311W |
| Max Power Dissipation @ 240V | 23W | 28W |
| Max Power Dissipation @ 110V | 29W | 41W |
| Internal Fuse | T6.3A (time delay) 5×20 mm | T8A (time delay) 5×20 mm |
| Feature | Specification |
|---|---|
| Battery Voltage | 12VDC / 24VDC |
| Battery Type | Nickel-Cadmium (sealed & non-sealed) |
| Rated Charging Voltage (Uc) | 14.2VDC (2.37V/cell) / 28.4VDC (2.37V/cell) |
| Boost Charging Voltage | +4.4% |
| Max Charging Current | 12A (1BAT004) / 10A (1BAT005) |
| Efficiency | ≥87.2% (1BAT004) / ≥90.2% (1BAT005) |
| Protection Features |
|---|
| Overload with current limit |
| Battery polarity inverted |
| Output short circuit |
| Output voltage variation (line regulation) <1% |
| Output variation (temperature) <1% |
| Output variation (load regulation) <1% |
| Ripple & noise <1% |
| Indicator | Description |
|---|---|
| Green LED (ON) | Power ON |
| Yellow LED (CHG) | Charging current ≥30% |
| Red LED (ALA) | Overload & short circuit |
| Red LED (REV) | Battery reverse polarity |
| Feature | Value |
|---|---|
| Rated Insulation Voltage (Ui) | 250V |
| Protection Class | Class II / SELV |
| Double Insulation | Between supply, battery, enclosure, and alarm relay |
| Power Frequency Withstand Voltage | 5kV |
| Feature | Value |
|---|---|
| Operating Temperature | -30°C to +55°C (no derating) |
| Extended Operating Temp | -30°C to +70°C (derating -1.5%Ic/°C) |
| Storage Temperature | -30°C to +80°C |
| Relative Humidity | <80% |
| Pollution Degree | 2 |
| Overvoltage Category | 2 |
| Climatic Sequence | Z/ABDM (IEC/EN 60068-2-61) |
| Shock Resistance | 15g |
| Vibration Resistance | 0.7g |
| Connection Type | Specification |
|---|---|
| Battery Terminals | Screw type, 0.2 – 6 mm² (30–10 AWG), Torque 0.5 Nm |
| Supply Terminals | Screw type, 0.2 – 2.5 mm² (30–12 AWG), Torque 0.5 Nm |
| Relay & Boost Terminals | Screw type, 0.2 – 2.5 mm² (30–12 AWG), Torque 0.5 Nm |
| Feature | Value |
|---|---|
| Version | Base mount / Internal panel |
| Material | Polycarbonate |
| Protection Degree (Front) | IP20 |
| Weight | 710 g |
| Certification | Standard |
|---|---|
| Certifications Obtained | cURus |
| Standards Compliance | IEC/EN 60950-1, IEC/EN 61558-2-16, IEC 61000-3-2, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 60950-1, CSA C22.2 No. 60950-1 |

Excel Industrial Services supplies the following Tornatech spare parts in Pakistan:
Excel Industrial Services is the official solution provider for Tornatech fire pump controllers in Pakistan, offering:
We bridge the gap between Tornatech’s global quality and Pakistan’s local needs, making sure fire protection systems stay compliant, reliable, and future-ready.
Controller model GPD is supplied with two battery chargers.
Each battery charger is connected to each diesel engine battery.
Each battery charger is equipped with its own individual transformer and circuit breaker.
The battery chargers have RS485 communication ports to communicate with the main mother board.
Battery charger #1 is powered by transformer XTR1 and protected by circuit breaker CB1.
Battery charger #2 is powered by transformer XTR2 and protected by circuit breaker CB2.
The controller has a visual and audible indication for failure of any battery charger.
The fire pump controller is equipped with an audio and visual alarm in case either of the battery chargers fails.
A battery charger failure alarm can be initiated by either the battery charger itself or by the main mother board.
The model BCE battery charger is designed to annunciate a charger failure if any of the following conditions occur:
Under amperage
The fire pump controller will initiate a battery charger failure if the RS485 communication is lost between either of the chargers and the main mother board for more than 1 minute.
This alarm will be visually indicated on the controllers main display screen.
If the « Charger Communication Loss » alarm is visually indicated, this means that the either of the battery chargers have lost communication with the main mother board. This may have been caused by a bad connection, broken connection or a defective electronic component.
A « Charger Communication Loss » alarm means that the battery charger is not 100% effective. For example the voltage and amperage readings might not be precise. However, the fire pump controller itself is fully 100% functional.
Important Note: To silence to audible alarm the HAND-OFF-AUTOMATIC selector switch must be placed to the OFF position. Placing it to OFF inhibit automatic operation of the controller so user must place controller back to AUTO.
The battery charger requires several seconds after energization (Initialization Mode) before it starts outputting amperage.
Once the initialization mode is over, the battery chargers enter into BULK mode which will deliver 8.0A (factory regulated not field adjustable). During BULK mode, the battery voltage slowly and gradually increases. Once the batteries reach 28.8V, the battery chargers enter OVERCHARGE mode.
In OVERCHARGE mode, the battery voltage is regulated at 28.8V and amperage decreases slowly while still charging the batteries. When the amperage reaches
3.0A, the chargers enter into FLOAT mode
In FLOAT mode the voltage is regulated at 25.8V and the amperage will vary in reference to the quality and stability of the batteries themselves and the consumption of the fire pump controller. The amperage can vary between 0 and 2.0A (max.). If the charging amps surpass 2.0A, the battery charger with enter BULK charge mode and the sequence re-starts.

In the above graphic, the blue curve represents the amperage delivered to the battery in function of time. The red curve represents the voltage of the battery over time
Note: If the consumption of the battery is above 2.0A (loss of excessive charge), the charger will switch from OVERCHARGE mode to BULK mode which will/can cause the battery to boil.
Parameter configuration is done at the factory as follows;

The above is for information only. The user cannot and must not make any changes
Battery chargers installed in controller.

Visual indications (LED’s) are arranged vertically along the right side of the charger.


Visual indicators (LED’s) description :
o Note: While the charger is in BULK mode, the temperature of the transformer is high. This is a normal occurrence.
IMPORTANT: The fuse situated on the battery charger circuit board is of type SLO-BLO 3AG-32VDC-20A. It is imperative that this type/model fused is used for the proper and safe functioning of the battery charger.
TornatechBatteryCharger #TornatechBatteryChargers #FirePumpBatteryCharger #AutomaticBatteryCharger #IndustrialBatteryCharger #12VBatteryCharger #24VBatteryCharger #NickelCadmiumBatteryCharger #NiCadBatteryCharger #SealedBatteryCharger #NonSealedBatteryCharger #ULApprovedBatteryCharger #FMApprovedBatteryCharger #CSAApprovedBatteryCharger #IECApprovedBatteryCharger #BatteryChargerPakistan #FirePumpChargerPakistan #BatteryChargerReplacement #BatteryChargerRepair #BatteryChargerMaintenance #Tornatech1BAT004 #Tornatech1BAT005 #1BAT004Charger #1BAT005Charger #Tornatech12VCharger #Tornatech24VCharger #HighEfficiencyBatteryCharger #TornatechNiCadCharger #EngineDrivenPumpCharger #DieselPumpBatteryCharger #FirePumpPanelCharger #DualBatteryCharger #NFPA20BatteryCharger #ULFMBatteryCharger #TornatechChargerModels #IndustrialChargerModels #TornatechChargerSpecs #BatteryChargerTechnicalSpecs #OverloadProtectedCharger #ReversePolarityProtection #ShortCircuitProtectedCharger #RippleNoiseFreeCharger #LEDIndicatorCharger #PowerOnLEDCharger #ChargeStatusLEDCharger #OverloadAlarmCharger #ReversePolarityAlarmCharger #HighEfficiencyCharger #PolycarbonateCharger #IP20BatteryCharger #cURusCertifiedCharger #CSA60950BatteryCharger #UL60950BatteryCharger #IEC60950BatteryCharger #DurableBatteryCharger #FirePumpBatterySupport #ExcelIndustrialServices #ExcelIndustrialServicesPakistan #ExcelBatteryChargerPakistan #ExcelTornatechPakistan #TornatechChargerPakistan #TornatechBatteryPakistan #BatteryChargerSupplierPakistan #BatteryChargerDistributorPakistan #BatteryChargerStockPakistan #BatteryChargerSparePartsPakistan #BatteryChargerRepairPakistan #BatteryChargerMaintenancePakistan #FirePumpChargerSparePartsPakistan #TornatechSparePartsPakistan #ExcelChargerSolutions #ExcelFirePumpSolutions #ExcelSafetySolutions #BatteryChargerExpertsPakistan #FirePumpChargerExpertsPakistan #TornatechFirePumpControllers #TornatechPanels #DieselFirePumpControllers #EngineDrivenFirePumpControllers #NFPA20Controllers #ULFMFirePumpControllers #FirePumpPanelsPakistan #TornatechRepairPakistan #TornatechMaintenancePakistan #TornatechReplacementPanels #SparePartsForTornatech #FirePumpSystemPakistan #ExcelFirePumpPakistan #TornatechSupportPakistan #CertifiedFirePumpControllers #IndustrialFirePumpSystems #GlobalFirePumpControllers #CanadianFirePumpPanels #BatteryChargersForFirePumps #TornatechChargerServicePakistan