UL listed Fire Alarm For Small and Medium-Sized Buildings

 

UL LISTED ADDREASSABLE FIRE ALARM SYSTEM

 1 Loop Panel x 127 devices

2 loop Pan/254 Devices each”

Our Brand have been engaged in fire security for over 15yrs by providing a variety of residential, commericial and industrial fire security solution, they ‘re now also providing OEM & ODM services for Schneider, Bosch, Siemens, etc.

Our offered brand has complete solution for Analog addressable fire detection alarm system, all devices are UL listed, supports 1 Loop Panel x 127 addressable devices I 2 Loops Panel x 254 addressable devices + 40 configurable zones by each loop, each device can be addressed and can be assigned to unique address to one of 40 zones, users can easily figure out when and where the fire breaks out. In addition, our fire system is with self-test function and installed followed by NFPA 72, very practical and easy to install.

” 3D Monitoring System Integration Available”

 • 32 bit processor Arm Cortex M3
• High/Low voltage separately protection circuit for safety
• Pluggable Loop PCB board available
• Networking up to 64 panels
• AC type detector integration available by I/O module 621
• Loop Options: 1 loop; 1 loop expanded to 2-loops; 2-loops
• High contrast backlit LCD provides 4 rows of 40 characters
for device and system status
• 4 Access Levels & 4000 events history log
• Day/night mode configurable
• Support 1 loop panel x 127 addressable devices & 2 Loop panel x 254 addressable devices + 40 configurable zones/each loop
• Automatic device type-code verification

Addressable Fire Alarm Control Panel
"UL Listed"

  • •Power: Input: AC(100 ~ 240)V/ 50/60Hz
  •  Emergency power supply: 12Ah @ 24V (2 x DC 12V)
  • Battery fault voltage: ≤ DC 20V
  • Standby current: 100mA @ DC 20 ~ 28V
  • Loop current: 200mA
  • Relay output: 3 x (1.0 A @ DC 30V /1A @AC 240V)
  • Humidity range: 0% – 95%
  • Temperature range: 0 oC ~ +49 oC
  • Standard: UL268:2009
  • Support Ethernet, RS485 interface, USB, PC software
  • Transmission distance up to 3KM, stable and reliable

Addressable Smoke Detector Device
(UL listed)

  • • Operating Voltage Range:16~33VDC

    • Standby current: < 200uA@24VDC

    • Action current: < 6mA

    • Sensitivity: 89uA – 94uA

    • 3 levels Smoke Sensor Sensitivity (NORMAL/LOW/HIGH)

    • Two fire LEDs allows 360° viewing

    • Standard: UL268:2009

    • Humidity range: < 93%

    • Temperature range: 0 oC-49 oC

    • Size: Ф150*67mm

    • Conventional Smoke detector is available for option.

  •  

Addressable Heat Detector Device
(UL listed)

• Operating Voltage Range:16~33VDC

• Standby current: < 200uA@24VDC

• Action current: < 6mA

• Sensitivity: 89uA – 94uA

• 3 levels Smoke Sensor Sensitivity (NORMAL/LOW/HIGH)

• Two fire LEDs allows 360° viewing

• Standard: UL268:2009

• Humidity range: < 93%

• Temperature range: 0 oC-49 oC

• Size: Ф150*67mm

• Conventional Smoke detector is available for option.

Addressable Manual Call Point
(UL listed)

• Standby current: < 200uA @24VDC
• Temperature range: 0 oC ~ +49 oC
• Humidity range: 0%-93%(RH)
• Standard: UL38
• Size: 138*104*55mm
• Addressable type

Addressable LED Sounder Strobe
(UL listed)

• Operating Voltage Range:16~33VDC
• Light intensity: 15cd,30cd,75cd,110cd,user selectable
• Sound mode: Intermittent sound, Continuous sound, Optional
•Temperature range: 0 oC ~ +49 oC
• Humidity range: 0% – 93% (RH)
• Size: 140*120*50mm
• Low Frequency 520HZ-Waking Effectiveness
• Synchronization
• Ceiling mount pending
• Self-test function

Addressable Alarm Bell
(UL listed)

• Operating Voltage Range:16~33VDC
• Standby current: 0 A
• Alarm Current: 25 mA
• Alarm volume: ≥ 95 dB @ 1 m
• Terminal line: (0.4 ~ 2.5) mm2
• Temperature range: 0 oC ~ +65 oC
• Humidity range: 0%-93% (RH)
• Storage temperature: -25 oC ~ +80 oC
• Storage humidity: 0%-98% (RH)
• Size: Ф152*60mm

Addressable Input/Output Module
(UL listed)

• Operating Voltage Range: 16~33VDC
• Loop current: 200mA
• Relay output: 2A, 30VDC; 0.5A 125VAC
• Temperature range: 0oC ~ +49oC
• Humidity range: 0% – 93%(RH)
• Size: 124*124*63mm
• AC type detector integration available by I/O module GS621
• Optional input/output

Addressable Isolator Module
(UL listed)

• Operating Voltage Range:16~33VDC
• Standby current: ≤0.6mA
• Work current: < 30mA
• Relay output: 1A, 30VDA; 1A 240VAC
• Temperature range: 0 oC ~ +49 oC
• Humidity range: 0%-93%(RH)
• Size: 124*124*63mm

Handheld Programmer
(UL listed)

 

  • Operating Voltage: 6V (Four AA batteries)
  • Standby Current: ≤ 40mA
  • Action Current: ≤ 100mA
  • Environmental Temperature: -20℃~ 60℃, dry
  • Relative Humidity: ≤ 95%, non-condensing
  • Material of Enclosure: ABS, white

Integrated Security Panel

  • Integrate devices on tablet
  • Easy installation
  • Battery/3G back up for power outage
  • Increase data security
  • Logic works in local
  • API is ready for others servers
  • Smart home and IP Camera integration
  • Connect internet and update to personal house keeping
  • Automation Setting